Drive condition: Shows the drive status in "Drive bayxx" "Status: yy" "Used hours:
zz" format.
xx: Drive bay number.
yy: Drive status in one of the representations below.
"Healthy": Normal
"Not Connected": Not physically installed
"Smart Detected": SMART detected
"Offline": Offline (D Model and B Model displayed)
"Offline" (Incomplete data): Offline due to data mismatch (B Model only)
"Rebuild": Rebuilding (D Model only)
"Overrun": Used hours exceeded
"Unknown": Unknown
"Smart Detected, Overrun": "Smart Detected" and "Overrun" at a time
zz: Drive used hours
Memory condition: Shows the status of memory in "DIMMxx status: yy" format.
xx: Memory slot name, where "A" represents DIMM A and "B" represents
DIMM B.
yy: Status in one of the representations below.
"Normal": Normal status
"Error": Highly frequent error correction status
"Not Mounted": Not mounted status
RAS Setting section: Shows RAS software settings in subsections.
Automatic shutdown setting: Shows the settings for automatic shutdown in "Fan:
xx" "Temperature: yy" "Remote shutdown: zz" format.
xx: Setting of automatic shutdown upon fan error. "ON" represents enabled and
"OFF" represents disabled.
yy: Setting of automatic shutdown upon temperature error. "ON" represents
enabled and "OFF" represents disabled.
zz: Setting of automatic shutdown upon remote shutdown signal input to
external contact. "ON" represents enabled and "OFF" represents disabled.
Watchdog timer setting: Shows the settings for watchdog timer in "Retrigger type:
xx" "Timeout: yy" "Interval: zz" format.
xx: Type of retrigger, where "Automatic" represents automatic execution of
retrigger, "Application" represents execution of retrigger by application program,
and "Not used" represents no use of retrigger.
yy: Timeout value for automatic execution of retrigger. "ON" represents
enabled and "OFF" represents disabled.
zz: Value of retrigger interval for automatic execution of retrigger.
7-29