Processing received frames
On this WBM page, you specify the configuration of the port properties for receiving frames.
Description
Table 1 has the following columns:
● All ports
Shows that the settings are valid for all ports of table 2.
● Priority / Port VID / Acceptable Frames / Ingress Filtering
In the drop-down list, select the setting for all ports. If "No Change" is selected, the entries
of the corresponding column in table 2 remain unchanged.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
● Port
Shows the available ports.
● Priority
Select the required priority assigned to untagged frames.
The CoS priority (Class of Service) used in the VLAN tag. If a frame is received without a tag,
it will be assigned this priority. This priority specifies how the frame is further processed
compared with other frames.
There are a total of eight priorities with values 0 to 7, where 7 represents the highest priority
(IEEE 802.1p Port Priority).
● Port VID
Select the required VLAN ID. Only VLAN IDs defined in "VLAN > General" can be selected.
If a received frame does not have a VLAN tag, it has a tag with the VLAN ID specified here
added to it and is sent according to the rules at the port.