Configuring with Web Based Management
4.9 "Security" menu
● Shared Secret Conf.
Enter your access ID again as confirmation.
● Max. Retrans.
Here, enter the maximum number of retries for an attempted request.
The initial connection attempt is repeated the number of times specified here before another
configured RADIUS server is queried or the login counts as having failed. As default 3 retries
are set, this means 4 connection attempts. The range of values is 1 to 5.
● Primary Server
Using the options in the drop-down list, specify whether or not this server is the primary
server. You can select one of the options "yes" or "no".
● Test
With this button, you can test whether or not the specified RADIUS server is available. The
test is performed once and not repeated cyclically.
● Test Result
Shows whether or not the RADIUS server is available:
– Not reachable
– Reachable, key not accepted
– Reachable, key accepted
Procedure
Entering a new server
1. Click the "Create" button. A new entry is generated in the table.
The following default values are entered in the table:
– RADIUS Server Address: 0.0.0.0
– Server Port: 1812
– Max. Retrans.: 3
– Primary server: No
2. In the relevant row, enter the following data in the input boxes:
– RADIUS Server Address
– Server Port
– Shared Secret
– Shared Secret Conf
– Max. Retrans.: 3
– Primary server: No
264
The IP address is not reachable.
The IP address is reachable, the RADIUS server is, however, not running.
The IP address is reachable, the RADIUS server does not, however accept the shared
secret.
The IP address is reachable, the RADIUS server accepts the specified shared secret.