Configuring with Web Based Management
4.5 "System" menu
Description
The table has the following columns:
Select the client type for which you want to make settings:
– E-mail
– Log Table
– Syslog
● Severity
Select the required severity. The following settings are possible:
– Info
– Warning
– Critical
4.5.6

SMTP client

4.5.6.1

General

Network monitoring with e-mails
If events occur, the device can automatically send an e-mail, e.g. to the service technician. The
e-mail contains the identification of the sending device, a description of the cause in plain text,
and a time stamp. This allows centralized network monitoring to be set up for networks with few
nodes based on an e-mail system.
142
Client Type
Sending system event messages by e-mail.
Entry of system events in the log table.
Entry of system events in the Syslog file.
The messages of all severities are sent or logged.
The messages of this severity and the "critical" severity are sent or logged.
Only the messages of this severity are sent or logged.
SCALANCE S615 Web Based Management