● Acceptable Frames
Specify which types of frames will be accepted. The following alternatives are possible:
– Tagged Frames Only
– All
● Ingress Filtering
Specify whether the VID of received frames is evaluated.
You have the following options:
– Enabled
– Disabled
Steps in configuration
1. In the row of the port to be configured, click on the relevant cell in the table to configure it.
2. Enter the values to be set in the input boxes as follows.
3. Select the values to be set from the drop-down lists.
4. Click the "Set Values" button.
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08
The device discards all untagged frames. Otherwise, the forwarding rules apply
according to the configuration.
The device forwards all frames.
The VLAN ID of received frames decides whether they are forwarded: To forward a
VLAN tagged frame, the receiving port must be a member in the same VLAN. Frames
from unknown VLANs are discarded at the receiving port.
All frames are forwarded.
Configuring with Web Based Management
4.7 "Layer 2" menu
221