Button

Functionality
The SELECT/SET button is used to:
● Restart
● Load new firmware
● Reset to factory settings.
You will find a detailed description of the functions in the operating instructions for the device.
On this page, the functionality of the button can be restricted.
Description
The following functionality is possible:
● Restart / Restore Factory Defaults
When disabled, the SELECT/SET button cannot be used for a restart or to restore factory
settings.
You will find more information on how to restore the device to the factory defaults despite
disabled functions in the section "Upkeep and maintenance (Page 301)".
4.5.11

Syslog Client

On this page, you can specify whether the syslog messages are sent unencrypted or encrypted.
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08
CAUTION
Button function "Restart / Restore Factory Defaults" active during startup
If you have disabled this function in your configuration, disabling is only valid during
operation. When restarting, for example after power off, the function is active until the
configuration is loaded and the device can therefore inadvertently be reset to the factory
settings. This may cause unwanted disruption in network operation since the device then
needs to be reconfigured. An inserted PLUG is also deleted and returned to the status as
shipped.