Configuring with Web Based Management
4.5 "System" menu
● Time
Select the setting from the drop-down list. The following settings are possible:
– Manual
– SIMATIC Time
– SNTP Client
– NTP Client
● SNMP
Select the protocol from the drop-down list. The following settings are possible:
– "-" (SNMP disabled)
– SNMPv1/v2c/v3
– SNMPv3
● SNMPv1/v2 Read Only
Enable or disable write access to SNMP variables with SNMPv1/v2c.
● SNMPv1 Traps
Enable or disable the sending of SNMPv1 traps (alarm frames). You can configure other
settings in "System > SNMP > Traps".
● SINEMA Configuration Interface
If the SINEMA configuration interface is enabled, you can download configurations to the
device using STEP 7 Basic / Professional.
● DHCP Client
Enable or disable the DHCP client. You can configure other settings in "System > DHCP".
● DUID Type
Specify which DUID type is used. The DUID types are defined in RFC 3315.
– DUID-LLT
– DUID-EN
– DUID-LL
116
The system time is set manually. You can configure other settings in "System > System
Time > Manual Setting".
The system time is set using a SIMATIC time transmitter. You can configure other
settings in "System > System Time > SIMATIC Time Client".
The system time is set via an SNTP server. You can configure other settings in "System
> System Time > SNTP Client".
The system time is set via an NTP server. You can configure other settings in "System
> System Time > NTP Client".
Access to device parameters via SNMP is not possible.
Access to device parameters is possible with SNMP versions 1, 2c or 3. You can
configure other settings in "System > SNMP > General".
Access to device parameters is possible only with SNMP version 3. You can configure
other settings in "System > SNMP > General".
DUID is based on the link layer address of the interface and a time stamp
DUID is assigned by the vendor (EN = enterprise number)
DUID is based on the link layer address of the interface
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08