Siemens SIMATIC NET SCALANCE S615 Configuration Manual page 57

Industrial ethernet security web based management
Hide thumbs Also See for SIMATIC NET SCALANCE S615:
Table of Contents

Advertisement

Type of notifica‐
Di
VPN
tion
gi‐
tun‐
tal
nel
In
Digital Input
x
Read out the
x
status of the
MIB variable
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08
Behavior if there is a status change
x
Controls the digital output or signals the status change with the "DO" LED.
A consumer can be connected to the digital output. You will find information on connecting in
the operating instructions of the devices. The consumer signals a status change.
Note
You can control the digital output directly via CLI or SNMP. In the WBM and CLI, you can
configure the use of the digital output in "Events". Do not control the digital output directly when
you use this in the WBM and CLI.
-
Using the private MIB variable snMspsDigitalInputLevel, you can read out the status of the
digital input.
● OID of the private MIB variable snMspsDigitalInputLevel:
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).siemen
s(4329).industrialComProducts(20).iComPlatforms(1).simaticNet(1).
snMsps(1).snMspsCommon(1).snMspsDigitalIO(39).snMspsDigitalIOObje
cts(1).snMspsDigitalInputTable(2).snMspsDigitalInputEntry(1).snMs
psDigitalInputLevel(6)
● values of the MIB variable
1: Signal 0 at the digital input (DI)
2: Signal 1 at the digital input (DI)
Technical basics
3.5 Security functions
57