Procedure
Configure error monitoring for a port
1. From the relevant drop-down list, select the options of the slots / ports whose connection
status you want to monitor.
2. Click the "Set Values" button.
Configure error monitoring for all ports
1. Select the required setting from the drop-down list of the "Setting"column.
2. Click the "Copy to table" button. The setting is adopted for all ports of table 2.
3. Click the "Set Values" button.
4.5.13

PLUG

4.5.13.1

Configuration

NOTICE
Do not remove or insert a C-PLUG / KEY-PLUG during operation!
A PLUG may only be removed or inserted when the device is turned off.
The device checks whether or not a PLUG is present at one second intervals. If it is detected
that the PLUG was removed, there is a restart. If a valid KEY-PLUG was inserted in the device,
the device changes to a defined error state following the restart. With SCALANCE M, the
available wireless interfaces are deactivated in this case.
If the device was configured at some time with a PLUG, the device can no longer be used
without this PLUG. To be able to use the device again, reset the device to the factory settings.
Information about the configuration of the KEY-PLUG
This page provides detailed information about the configuration stored on the C-PLUG. It is also
possible to reset the PLUG to "factory defaults" or to load it with new contents.
Note
Incompatibility with previous versions with PLUG inserted
During the installation of a previous version, the configuration data can be lost. In this case, the
device starts up with the factory settings after the firmware has been installed. In this situation,
if a PLUG is inserted in the device, following the restart, this has the status "Not Accepted" since
the PLUG still has the configuration data of the previous more up-to-date firmware. This allows
you to return to the previous, more up-to-date firmware without any loss of configuration data.
If the original configuration on the PLUG is no longer required, the PLUG can be deleted or
rewritten manually using "System > PLUG".
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08
Configuring with Web Based Management
4.5 "System" menu
179