11.4.2 'Manual zone'

Typical application
'Standard':
Evaluation of manual fire detectors
'ALARM sub-system':
Evaluation of a sub-system that is
connected via an input
'Local ALARM':
Evaluation of manual fire detectors
that generate only a local alarm
'Redundancy ALARM':
Evaluation of manual fire detectors
that generate a redundancy alarm

11.4.3 'Technical zone'

Main features and typical application
'Standard (ack./latching)':
The event must be acknowledged with
latching
'Standard (ack./non-latching)':
The event must be acknowledged
without latching
'Fault sub-system':
Evaluation of fault messages of a
connected sub-system
'Sub-system OFF':
Evaluation of switched off messages of a
connected sub-system
Building Technologies
Fire Safety
'Manual call points' are evaluated in the 'Manual zone'. The 'Zone' can however
also be configured for inputs or collective detector lines. The danger signals are
evaluated with an OR link. Each manual call point in the 'Zone' can generate an
alarm, but not a ↑ pre-alarm.
You can select between a variety of different templates that are pre-configured for
various applications for the creation of a 'Manual zone'.
The following table shows the properties of the templates along with the event
category and the event text of the message that is generated with an alarm.
Typical event category
' ----Manual Fire ALARM'
' ----Manual Fire ALARM'
' ----Manual Fire ALARM'
' ----Manual Fire ALARM'
Table 7: Properties of the templates
Text that is shown on the display of the Person Machine Interface when the event
1
occurs.
In 'Technical zone', inputs for ↑ technical messages, e.g., fault or danger by
extraneous equipment, are evaluated.
You can select between a variety of different templates that are pre-configured for
various applications for the creation of a 'Technical zone'. The following table
shows the properties of the templates along with the event category and the event
text of the message that is generated with an event. The templates are all with
↑ single-detector dependency and without 'Pre-ALARM'.
Typical event category
' --Other technical message'
' --Technical message:
programmable'
' --Other fault'
' --Sub-system isolation'
'Detection' task card
'Zone'
Event text
1
'Manual FIRE ALARM'
'ALARM sub-system'
'Manual local ALARM'
'Redundancy ALARM'
Event text
1
'Technical message'
'Technical message'
'Fault sub-system'
'Sub-system OFF'