Ac Phases Connection Process Via A Terminal - Ingeteam INGECON SUN PowerMax TL U B 1000 Vdc Series Installation And Operation Manual

Table of Contents

Advertisement

Ingeteam
Phase connection via two terminals with two holes
E
B
C
A.
M12 DIN 933 screw.
B.
M12 NFE-25 511 M washer.
C.
Terminal. Diameter of the M12 hole, maximum thickness of 0.39 in (10 mm), maximum width of 1.3 in
(33 mm), vertical distance between holes of 13/4 in (44.5 mm).
D.
Busbar.
E.
M12 DIN 934 nut.
Neutral connection via a terminal with one hole
D
A.
M6 DIN 934 nut.
B.
M6 NFE-25 511 M washer.
C.
Terminal. Hole diameter of M6, maximum thickness of 0.39 in (10 mm), maximum width of 1.3 in
(33 mm).
D.
Busbar.

16.4.2. AC phases connection process via a terminal

Proceed in the following order for each phase:
1.
Clean the contact surfaces on both the terminal and the busbar with a clean cloth and ethanol.
114
D
C
C
B
B
A
A
ABK2027IQE01_A - Installation and Operation Manual