gPV class.
Rated current of 50 A ~ 630 A, depending on the specifications of the unit.
Fuses of the following sizes and formats are allowed:
Number of inputs
5
6
7
8
9
10
11
12
13
14
15
depending on whether it is installed on the positive pole or both poles.
(1)
2XL Mechanical specifications
ABK2027IQE01_A - Installation and Operation Manual
Number of fuses
Fuse holder base size
5 or 10
(1)
6 or 12
(1)
7 or 14
(1)
8 or 16
(1)
9 or 18
(1)
10 or 20
(1)
11 or 22
(1)
12 or 14
(1)
13 or 26
(1)
14 or 28
(1)
15 or 30
(1)
max. 5.12 in (130 mm)
max. 8.07 in (205 mm)
max. 6.85 in (174 mm)
max. 5.28 in (134 mm)
Maximum size
3L
630 A
3L
630 A
3L
630 A
3L
630 A
3L
630 A
3L
630 A
3L
630 A
3L
630 A
2XL
400 A
2XL
400 A
2XL
400 A
max. 0.24 in (6 mm)
Ingeteam
Recommended size
with I
max
630 A
600 A
500 A
400 A
350 A
315 A
315 A
315 A
250 A
250 A
250 A
max. 2.4 in (61 mm)