AC connection
The AC phase busbars are located on the left or right side, depending on the unit configuration, and the cable entry
is done from the lower part of the enclosure that protects the connection. The following figure represents a cross-
section view of the enclosure.
Each phase has five connection positions per plate, with two holes per position. It is possible to connect one or two
wires per position (on one side of the busbar or on both), so the maximum number of wires per phase is ten (five
positions, two wires per position).
The dimensions of the inverter busbars are as follows:
ABK2027IQE01_A - Installation and Operation Manual
T
S
g
a
10.82 in (275 mm)
b
2.28 in (58 mm)
c
2.13 in (54 mm)
d
0.39 in (10 mm)
R
e
1.75 in (44.5 mm)
f
0.55 in (14 mm)
g
2.83 in (72 mm)
Ingeteam
e
d
109