14. D-STAR OPERATION (ADVANCED)

EMR communication

The Enhanced Monitor Request (EMR)
communication function can be used in only the
DV mode. Using the EMR function, no call sign
setting is necessary.
LInformation
• All transceivers that can receive an EMR signal
automatically open their digital squelch to receive
the signal. DO NOT use this function except in the
case of emergency.
• When an EMR signal is received, the audio (voice)
is heard at the set level, even if the volume setting
level is set to the minimum level.
• The EMR communication function is automatically
turned OFF when you turn OFF the transceiver.
Example: Transmitting from the "Hirano"
repeater using the EMR function.
1. Open the EMR screen.
» SET > DV SET > EMR
2. Touch "ON."
3. To close the DV SET screen, push
several times.
• Returns to the standby screen, and "EMR" is
displayed.
4. Hold down [PTT] to transmit.
L"EMR" blinks on a station that receives the EMR
signal. The audio (voice) is heard at the set
EMR AF Level, or the
whichever is higher.
LTo cancel the EMR mode, touch "OFF" in step
2, or turn OFF the transceiver.

DAdjusting the EMR AF level

The audio output level, when an EMR signal is
received, is adjustable between 0 and 100%.
When an EMR signal is received, the audio is
heard at the preset level, or the
level, whichever is higher.
To turn OFF the setting, set to "0."
1. Open the "EMR AF Level" screen.
2. Touch [+] or [–] to adjust the EMR audio
3. To close the "EMR AF Level" screen, push
control level,
14-15
» SET > DV SET > EMR AF Level
output level between 0% (OFF) and 100%
(maximum). (Default: 50%)
several times.