15. ABOUT THE DV GATEWAY FUNCTION
Setting up a network
About the UDP Hole Punch function
When both the caller station and the called station use the Terminal or Access Point mode, the caller
station does not need to:
• Forward port 40000 when connecting to the Internet using the router.
• Use a device assigned a static or dynamic Global IP address.
CQ CQ CQ,
CQ CQ CQ,
this is JA3YUA.
this is JA3YUA.
Caller
Caller
LInformation
• Depending on your Network environment, you may not be able to use this function.
• The caller station must set "UDP Hole Punch" to "ON" in the IC-705 (When using the Internal Gateway function)
or RS-MS3W/RS-MS3A (When using the External Gateway function) to use this function.
» 2 > DV GW > Internal Gateway Settings > UDP Hole Punch
When not using this function, set "UDP Hole Punch" to "OFF."
• A few minutes* after the call, the caller station cannot receive from the called station. In this case, the caller
station must transmit to the called station again.
* Less than 3 minutes, depending on the router.
NOTE:
• When using the External Gateway function, use version 1.30 or later of the RS-MS3W/RS-MS3A application
software.
• The caller station cannot communicate with the called station when:
- The caller station is using an earlier version software or firmware.
- The called station using an earlier version software or firmware.
- The called station calls through a local repeater instead of using the Terminal or Access Point mode.
• Even if using the latest version, the called station needs to forward port 40000 when connecting to the
Internet using a router, or to use a device assigned a static or dynamic Global IP address to communicate
with the caller station.
Called
Called
INTERNET
INTERNET
No need to
forward port 40000�
INTERNET
INTERNET
Not forwarding
port 40000
15-5
Forward
port 40000�
Called
Called
JA3YUA,
JA3YUA,
this is JM1ZLK.
this is JM1ZLK.
Forwarding
port 40000
CQ CQ CQ,
CQ CQ CQ,
this is JM1ZLK.
this is JM1ZLK.
Caller
Caller