MUTOH ValueJet VJ-426UF Operation Manual page 9

Hide thumbs Also See for ValueJet VJ-426UF:
Table of Contents

Advertisement

Operation panel
Power button
Pressing this turns the power
on. Lights steady in blue when
the power is on.
Pressing this once more turns
the power off. Is unlit when the
power is off.
Flashes while data is being
received, in the sleep mode,
and at other times.
[Reference]
The
symbol means "standby". Even
when the power button is not turned
on, the printer consumes a tiny
amount of power so long as the power
cable is connected. This state is
referred to as the power being "off" in
this Manual.
[Option] indicators
Not functional.
These indicators do not light.
[Media Set] indicator
Lights steady green when a
media has been set in place and
the printer is ready to print.
[Low speed] indicator
Lights steady green, except
when [Low speed] is turned Off.
[Menu] key
Used for accessing and exiting
the menu.
[Pause] / [Cancel] key
Press this key to pause printing.
Holding this key pressed down
for 2 seconds or longer will
cancel the print job and delete
the data received.
When setting the menu:
Cancels a change of a setting
value.
[+] / [Set Media] key
Pressing this after setting a media
in place will put the printer into
ready-to-print status.
When setting the menu:
Press this to move to another
menu item
Press this to change a set value.
[ - ] / [Remove Media] key
Pressing this after printing will
enable replacement of the media.
When setting the menu:
Press this to move to another
menu item
Press this to change a set value.
Error indicator
Lights up in orange when an
error has occurred or a cover is
open.
Flashes when the ink is low.
Display
Displays the printer status,
setting menu, errors and so on.
[Cleaning Mode] indicators
Light steady green to indicate
the head cleaning mode.
[Enter] key
When you have set a media in
place, pressing and holding this
down for 2 seconds or longer
will run a media set check.
When setting the menu:
Press this to go to the menu
item you select.
Press this to confirm a set
value.
[<] / [Nozzle Check] key
Pressing and holding this down
for 2 seconds or longer will run
a nozzle check.
When setting the menu:
Press this to change a set value.
[>] / [Cleaning Mode] key
For changing the cleaning
mode.
Pressing and holding this down
for 2 seconds or longer will
execute head cleaning.
When setting menu:
Press this to move to a lower
level of menu items.
Press this to change a set value.
Name of each part
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents