Maintenance work on the superstructure
8.6 Hydraulic system
Establishing the
operating
conditions
S
8 - 44
After having changed the oil filters and topping up the oil, you must
re-establish the operating conditions.
Risk of damage to the hydraulic pumps
Open the valve prior to starting the engine.
This prevents damage to the hydraulic pumps.
Start the engine (from the crane cab).
Carry out all hydraulic functions several times to remove any air in
the system.
Check that none of the oil filters is leaking.
Check the oil level through the sight glass on the hydraulic oil tank.
Top up oil, if necessary;
Opening the valve
The plug (1) must be open.
Pull the locking bar (3).
Open the valve – lever (2) parallel to the line.
Insert the locking bar (3).
Close the flap (1).
à
p. 8 - 43.