Maintenance work on the carrier
7.3 Engine
7.3.5
7.3.6
Reducing the
interval
Prerequisites
7 - 18

General inspection

Investigate any unusual running noises from the engine.
Check the engine and the connections for leaks. If consumables are leaking;
à
Checking the oil level , p. 7 - 13,
à
Checking the coolant level , p. 7 - 17.
Check that pipes and hoses are tightly connected and undamaged.
If any damage is found, report it to
GROVE dealer or an authorised specialist workshop.

Have the radiator checked/cleaned

Under difficult operating conditions – at extremely sandy or dusty
locations or if there is a heavy density of fallen leaves – you must have the
radiator fins cleaned earlier than this.
– The truck crane must be supported on outriggers and must be level;
à
Operating Instructions .
– The main boom must be fully retracted and raised to 75°;
Instructions .
– The engine must be switched off and secured against unauthorised use;
à
p. 2 - 3.
– The working area around the carrier at the radiator unit must be freely
accessible.
– Trained repair crew and repair tools must be available.