Maintenance work on the carrier
7.5 Exhaust system with exhaust emission control
Checking
G
7 - 36
Risk of burns if the exhaust system is hot
During operation, the exhaust system heats up to 400 °C (750 °F). Wear
suitable gloves and wait until the exhaust system has cooled down.
Make sure not to touch any hot parts.
After checking
Start the engine.
Check the AdBlue system gauge on the display in the driver's cab;
à
p. 7 - 34.
Check whether exhaust gases are leaking from any damaged places in
the exhaust system.
Switch the engine off.
If you discover any damage
Have any damaged parts of the exhaust system replaced immediately by
Manitowoc Crane Care
Check the exhaust pipes (2) from the engine
(1) to the silencer (3) for damage.
The exhaust pipes (2) may not have any
holes or cracks.
Check that the area around the exhaust
pipes is free of loose components which
could burn by coming into contact with the
hot exhaust system.
Check the AdBlue injection nozzle (4)
for outer damage.
or an authorised GROVE dealer.
3 302 364 en