Huawei FusionModule1000B V100R003C00 Commissioning Manual page 6

Water-cooled it solution
Table of Contents

Advertisement

FusionModule1000B Water-Cooled IT Solution
Commissioning Guide
7.1 Power Supply and Distribution System Commissioning ............................................................................................ 44
7.1.1 Verifying the Switchover Between Two Power Supplies ......................................................................................... 44
Temperature ...................................................................................................................................................................... 45
7.2 Commissioning the Cooling System ........................................................................................................................... 46
7.3 Commissioning the Management System ................................................................................................................... 46
7.4 Commissioning the Fire Extinguishing System (Standard) ........................................................................................ 47
7.5 Fire Extinguishing System Commissioning (CE) ....................................................................................................... 58
8 Shutting Down and Powering Off .......................................................................................... 66
9 Commissioning Core Components.......................................................................................... 68
9.1 Commissioning Power Distribution Components ....................................................................................................... 68
9.1.1 Commissioning the Power Distribution Cabinet ..................................................................................................... 68
9.1.1.1 (Optional) Commissioning the 8D ATS ................................................................................................................ 69
9.1.1.2 (Optional) Commissioning the PD510 Electricity Meter ...................................................................................... 70
9.1.1.3 (Optional) Commissioning the MDU ................................................................................................................... 74
9.1.2 Commissioning the UPS5000-E .............................................................................................................................. 77
9.1.3 (Optional) Commissioning the UPS2000-G ............................................................................................................ 78
9.2 Commissioning Cooling Components ........................................................................................................................ 79
9.2.1 Commissioning Chillers .......................................................................................................................................... 79
9.2.2 Commissioning 30 kW Chilled Water Precision Air Conditioners .......................................................................... 80
9.2.2.1 Initial DIP Switch Configuration for T/H Sensors ................................................................................................ 82
9.2.2.2 Initial DIP Configuration for the Main Control Board ......................................................................................... 83
9.2.2.3 Teamwork Initial Configuration ............................................................................................................................ 84
9.2.2.4 Initial Configuration of Temperature and Humidity ............................................................................................. 91
9.2.3 (Optional) Commissioning Civil Air Conditioners .................................................................................................. 93
9.3 Commissioning Monitoring Components ................................................................................................................... 94
9.3.1 Commissioning Access Control Components .......................................................................................................... 94
9.3.2 (Optional) Registering a Fingerprint Scanner User ................................................................................................. 95
9.3.3 Initial Configurations for the Management System ................................................................................................. 96
9.4 Commissioning Fire Extinguishing Devices (Standard) ............................................................................................. 97
9.4.1 Commissioning the Fire Alarm Control Panel (standard) ........................................................................................ 97
9.4.2 Commissioning the Emergency Lights (standard) ................................................................................................... 99
9.5 Commissioning Fire Extinguishing Devices (CE) .................................................................................................... 100
9.5.1 Commissioning the Extinguishant Control Panel (CE) ......................................................................................... 100
9.5.2 Commissioning the Emergency Light (CE) ........................................................................................................... 101
9.6 Commissioning the VESDA ..................................................................................................................................... 102
10 Acronyms and Abbreviations ............................................................................................... 104
Issue 02 (2017-01-10)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Contents
v

Advertisement

Table of Contents
loading