Dlp-G20 Install Alarm Wires On The Mic-A/P (Etsi Only) - Cisco ONS 15454 Hardware Installation Manual

Hide thumbs Also See for ONS 15454:
Table of Contents

Advertisement

Installing the ONS 15454 M12 (ANSI and ETSI) Shelf
• Complete the
• Complete the
• Complete the
Stop. You have completed this procedure.

DLP-G20 Install Alarm Wires on the MIC-A/P (ETSI Only)

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Procedure
Step 1
Using 0.51 mm² or 0.64 mm² (#22 or #24 AWG) wires, connect the alarm and control wires on the appropriate
pins of the DB-62 connector. The pin connectors, signal names, and functions are listed in the following table.
Table 15: Alarm Pin Assignments
DB-62 Pin Connector
1
2
3
4
5
DLP-G24 Install Timing Wires on the Backplane (ANSI Only), on page 109
provisioning external timing.
DLP-G25 Install LAN Wires on the Backplane (ANSI Only), on page 110
external LAN connection. You must either install LAN wires on the backplane or connect a CAT-5
Ethernet cable to the LAN port on the TCC2/TCC2P/TCC3 card to create an external LAN connection.
TL1 Craft Interface Installation, on page 99
using the craft interface. Craft wires or the EIA/TIA-232 port on the TCC2/TCC2P/TCC3 card are
required to access TL1.
This task installs alarm cables on the MIC-A/P on the ONS 15454 ETSI so that
you can provision external (environmental) alarms and controls with the AIC-I
card.
DB-62 connector
0.51 mm² or 0.64 mm² (#22 or #24 AWG) wires
NTP-G6 Install the MIC-A/P and MIC-T/C/P FMECs (ETSI Only), on page 66
As needed
Onsite
None
Signal Name
ALMCUTOFF–
ALMCUTOFF+
ALMINP0–
ALMINP0+
ALMINP1–
DLP-G20 Install Alarm Wires on the MIC-A/P (ETSI Only)
to access Transaction Language One (TL1)
Function
Alarm cutoff
Alarm cutoff
Alarm input pair number 1
Alarm input pair number 1
Alarm input pair number 2