DLP-G23 Install Alarm Wires on the Backplane (ANSI Only)
Table 17: LAN Pin Assignments
LAN
LAN 1 Connecting to
DCE
switch)Cross-over
Ethernet cable
LAN 1Connecting to
DTE(a
PC/workstation or
router)Straight-through
Ethernet cable
Step 2
Return to your originating procedure (NTP).
DLP-G23 Install Alarm Wires on the Backplane (ANSI Only)
Purpose
Tools/Equipment
Prerequisite Procedures
Cisco ONS 15454 Hardware Installation Guide
106
RJ-45 Pin
1
2
(a hub or
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
2
The Cisco ONS 15454 ETSI is DCE.
This task installs alarm wires on the backplane so that you can provision external
(environmental) alarms and controls with the AIC-I card. If you are using the
AEP, do not perform this task.
Wire wrapper
#22 or #24 AWG (0.51 mm² or 0.64 mm²) wires
100-ohm shielded BITS clock cable pair #22 or #24 AWG (0.51 mm² or 0.64
mm²), twisted-pair T1-type
NTP-G5 Remove the Backplane Covers (ANSI Only), on page 63
RJ-45 Pin
Function
3
PNMSRX+white/green
6
PNMSRX–green
1
PNMSTXwhite/orange
4
—
5
—
2
PNMSTX–orange
7
—
8
—
PNMSRX+white/green
1
2
PNMSRX–green
3
PNMSTX+white/orange
4
—
5
—
6
PNMSTX–orange
7
—
8
—
Installing the ONS 15454 M12 (ANSI and ETSI) Shelf