Dlp-G680 Mount Multiple Ons 15454 Shelf Assemblies In A Rack - Cisco ONS 15454 Hardware Installation Manual

Hide thumbs Also See for ONS 15454:
Table of Contents

Advertisement

Installing the ONS 15454 M12 (ANSI and ETSI) Shelf
Step 4
Lift the shelf to the desired position in the rack.
Step 5
Align the screw holes on the mounting brackets with the mounting holes in the rack.
Step 6
Have one person hold the shelf in place while the other person uses the Phillips Dynamometric screwdriver
to install one mounting screw in each side of the assembly.
Step 7
When the shelf is secured to the rack, install the remaining mounting screws.
Note
Step 8
Use the hex tool to remove the temporary set screws.
Step 9
Return to your originating procedure (NTP).

DLP-G680 Mount Multiple ONS 15454 Shelf Assemblies in a Rack

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Note
A standard ETSI rack can hold three ONS 15454 ETSI shelf assemblies and two air ramps. When mounting
a shelf in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the
bottom of the rack. If the rack is provided with stabilizing devices, install the stabilizers before mounting or
servicing the unit in the rack.
Use at least one set of the horizontal screw slots on the shelf to prevent slippage.
This task installs multiple shelves in a rack.
Pinned hex key
#2 Phillips Dynamometric screwdriver
ETSI only:
Two M6 x 20 socket set screws (per shelf)
Eight M6 x 20 pan-head Phillips mounting screws (per shelf)
ANSI only:
Two #12-24 x 3/4 set screws (48-1003-XX) (per shelf)
Eight #12-24 x 3/4 pan-head Phillips mounting screws (48-1004-XX, 48-1007-XX)
(per shelf)
NTP-G305 Unpack and Inspect the ONS 15454, ONS 15454 M2, and ONS 15454
M6 Shelves, on page 20
As needed
Onsite
None
DLP-G680 Mount Multiple ONS 15454 Shelf Assemblies in a Rack
Cisco ONS 15454 Hardware Installation Guide
39