Installing the ONS 15454 M12 (ANSI and ETSI) Shelf
Required/As Needed
Onsite/Remote
Security Level
Procedure
Step 1
For ONS 15454 ETSI shelves:
a) Unscrew the nut holding the ground wire to the shelf. Remove the nut and washer.
b) Remove the ground wire from the shelf.
c) Hold the door at the top left corner and remove the door from its hinges as shown in the following figure.
Figure 34: Removing the ONS 15454 ETSI Front Door
Step 2
For ONS 15454 ANSI shelves:
a) To remove the door ground strap, perform the following:
As needed
Onsite
None
• To detach the ground strap from the front door, loosen the #6 Kepnut (49-0600-01) using the open-end
wrench. Detach the end of the ground strap terminal lug (72-3622-01) from the male stud on the
inside of the door.
DLP-G10 Remove the Front Door