Dlp-G589 Mount The Ons 15454 M2 Shelf On A Rack (One Person) - Cisco ONS 15454 Hardware Installation Manual

Hide thumbs Also See for ONS 15454:
Table of Contents

Advertisement

Installing the ONS 15454 M2 Shelf
Step 10
Align the screw holes on the mounting bracket with the screw holes on the left side of the chassis.
Step 11
Insert the screws and tighten them to a torque value of 11.5 in-lb (1.3 N-m).
Step 12
Place the left top air deflector flush against the left side of the chassis as shown in Diagram 3 of
Mounting the Bracket with Air Deflectors (Front-to-Top) on the ONS 15454 M2 Shelf for ETSI Rack
Configuration, on page
Note
Step 13
Align the screw holes with the screw holes of the mounting bracket and the chassis.
Step 14
Insert the screws and tighten them to a torque value of 11.5 in-lb (1.3 N-m). See Diagram 4 of
Mounting the Bracket with Air Deflectors (Front-to-Top) on the ONS 15454 M2 Shelf for ETSI Rack
Configuration, on page
Figure 129: Mounting the Bracket with Air Deflectors (Front-to-Top) on the ONS 15454 M2 Shelf for ETSI Rack Configuration
Step 15
Return to your originating procedure (NTP).

DLP-G589 Mount the ONS 15454 M2 Shelf on a Rack (One Person)

Purpose
209.
If the 100G-LC-C, 10x10G-LC, or CFP-LC cards are to be installed in the ONS 15454 M2 shelf,
do not mount the left top deflector (exhaust air deflector). Use the standard brackets directly to
mount the ONS 15454 M2 shelf.
209.
This task allows one person to mount the shelf in a rack.
DLP-G589 Mount the ONS 15454 M2 Shelf on a Rack (One Person)