Installing the ONS 15454 M6 Shelf
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
We recommend the use of RJ-45 port (craft terminal port or the EMS port) on the ECU module to establish
LAN connectivity. The advantages of using the RJ-45 ports on the ECU module include:
• CAT-5 Ethernet cable connections can be managed better by routing the cable through the ECU module
• If the TNC, TNCE, TSC, or TSCE card fails, the LAN connection is not lost during the TNC, TNCE,
If the ECU module is absent, you can connect a CAT-5 Ethernet cable to the LAN port on the
TNC/TNCE/TSC/TSCE card to create an external LAN connection.
Note
You can use the same procedure to connect Multishelf Management ports of several chassis in MSM
configurations.
Note
To avoid duplex mismatch between EMS or craft terminal port and external LAN switch port, auto negotiation
must be enabled on the external LAN switch port.
Procedure
Step 1
Using 0.51 mm² or 0.64 mm² (#22 or #24 AWG) wire or a standard CAT-5 Ethernet cable, connect the wires
to the RJ-45 connector.
Step 2
Return to your originating procedure (NTP).
NTP-G308 Connect the ONS 15454 M6 Multishelf Node and the
ONS 15454 M6 Subtending Shelves
Purpose
NTP-G308 Connect the ONS 15454 M6 Multishelf Node and the ONS 15454 M6 Subtending Shelves
Standard CAT-5 Ethernet cable (straight-through for data terminating equipment
[DTE] or cross-over for data circuit-terminating equipment [DCE]) or RJ-45
connector Crimping tool for RJ-45 connector
0.51 mm² or 0.64 mm² (#22 or #24 AWG) wire, preferably CAT-5
NTP-G253 Install the ECU or ECU-S Module, on page
As needed
Onsite
None
cable exit area.
TSC, or TSCE card switch over.
Use this procedure to connect the ONS 15454 M6 multishelf node and the ONS
15454 M6 subtending shelves.
Cisco ONS 15454 Hardware Installation Guide
349.
407