Dlp-G588 Mounting The Bracket With Air Deflectors (Front-To-Top) On The Ons 15454 M2 Shelf For Etsi Rack Configuration - Cisco ONS 15454 Hardware Installation Manual

Hide thumbs Also See for ONS 15454:
Table of Contents

Advertisement

DLP-G588 Mounting the Bracket with Air Deflectors (Front-to-Top) on the ONS 15454 M2 Shelf for ETSI Rack Configuration

DLP-G588 Mounting the Bracket with Air Deflectors (Front-to-Top) on the ONS 15454 M2 Shelf for
ETSI Rack Configuration
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Caution
Use only the fastening hardware provided with the ONS 15454 M2 to prevent loosening, deterioration, and
electromechanical corrosion of the hardware and joined material.
Note
The air deflectors can be installed only in the front position of the chassis.
Procedure
Step 1
Place the right front air deflector flush against the right side of the chassis (see Diagram 1 of
Mounting the Bracket with Air Deflectors (Front-to-Top) on the ONS 15454 M2 Shelf for ETSI Rack
Configuration, on page
Step 2
Align the screw holes on the right front air deflector with the screw holes on right side of the chassis.
Step 3
Insert the screws and tighten them to a torque value of 11.5 in-lb (1.3 N-m).
Step 4
Place the air deflector cover on the rear end of the chassis.
Step 5
Insert the screws and tighten them to a torque value of 11.5 in-lb (1.3 N-m). See Diagram 2 of
Mounting the Bracket with Air Deflectors (Front-to-Top) on the ONS 15454 M2 Shelf for ETSI Rack
Configuration, on page
Step 6
Place the mounting bracket flush against the left side of the chassis (see Diagram 2 of
the Bracket with Air Deflectors (Front-to-Top) on the ONS 15454 M2 Shelf for ETSI Rack Configuration,
on page
Step 7
Align the screw holes on the mounting bracket with the screw holes on the left side of the chassis.
Step 8
Insert the screws and tighten them to a torque value of 11.5 in-lb (1.3 N-m).
Step 9
Place the mounting bracket flush against the right side of the chassis (see Diagram 2 of
the Bracket with Air Deflectors (Front-to-Top) on the ONS 15454 M2 Shelf for ETSI Rack Configuration,
on page
Cisco ONS 15454 Hardware Installation Guide
208
This task installs the bracket with air deflectors (front-to-top configuration) on
the ONS 15454 M2 shelf.
• #2 Phillips Dynamometric screwdriver
• Medium slot-head screwdriver
• Small slot-head screwdriver
NTP-G305 Unpack and Inspect the ONS 15454, ONS 15454 M2, and ONS 15454
M6 Shelves, on page 20
As needed
Onsite
None
209).
209).
209).
209).
Installing the ONS 15454 M2 Shelf
Figure 129:
Figure 129:
Figure 129: Mounting