Remote At Command Request Frame - 0X17 - Digi XBee 3802.15.4 User Manual

Radio frequency (rf) module
Table of Contents

Advertisement

Frame descriptions

Remote AT Command Request frame - 0x17

Description
Used to query or set device parameters on a remote device. For parameter changes on the remote
device to take effect, you must apply changes, either by setting the Apply Changes options bit, or by
sending an AC command to the remote.
Format
The following table provides the contents of the frame. For details on frame structure, see
format.
Frame
data
fields
Offset Description
Frame
3
type
Frame ID
4
64-bit
5-12
destination
address
16-bit
13-14
destination
address
15
Remote
command
options
AT
16-17
command
Command
18-n
parameter
Digi XBee® 3 802.15.4 RF Module User Guide
0x17
Identifies the data frame for the host to correlate with a subsequent
response (0x97). If set to 0, the device does not send a response.
This field is ignored if the 16-bit network address field equals anything other
than 0xFFFE. Do not use a broadcast address for remote AT commands
because a remote AT command is only expected to get a response from one
particular node.
Set to match the 16-bit network address of the destination, MSB first, LSB
last. Set to 0xFFFE if 64-bit addressing is being used.
Bit
Bit mask
1
0x02
4
0x10
Set all other bits to 0 so that they will not have unexpected effects in case the
other bits are defined later.
Command name: two ASCII characters that identify the command.
If present, indicates the parameter value you request for a given register. If
no characters are present, it queries the register.
Remote AT Command Request frame - 0x17
Description
Apply changes on remote. If not
set, the changes are not applied
until the next command with bit 1
set or until the AC command is
sent.
Send the remote command
securely.
API frame
200

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xbee 3 802.15.4

Table of Contents