My (Source Address) Command; Nb (Parity) Command - Digi XTend User Manual

Rf module
Table of Contents

Advertisement

AT Command: ATMT
Binary Command: 0x3D (61 decimal)
Parameter Range: 0 - 0xFF
Default Parameter Value:0 (no forced retransmissions)
Number of bytes returned: 1
Related Commands: Networking (DT, MK, MY, RN, TT), Serial Interfacing (BR, PK, RB, RO), RF Interfacing (FS)

MY (Source Address) Command

<Networking and Security> The MY command is used to set/read the Source Address of the RF module.
AT Command: ATMY
Binary Command: 0x2A (42 decimal)
Parameter Range: 0 - 0xFFFF
Default Parameter Value: 0xFFFF (Disabled - DT (Destination Address) parameter serves as both source and
destination address.)
Number of bytes returned: 2
Related Commands: DT (Destination Address), HP (Hopping Channel), ID (Modem VID), MK (Address Mask)

NB (Parity) Command

<Serial Interfacing> The NB command is used to select/read the parity settings of the RF module for UART
communications.
AT Command: ATNB
Binary Command: 0x23 (35 decimal)
Parameter Range: 0 - 4
Parameter
0
1
2
3
4
Default Parameter Value: 0
Number of bytes returned: 1
XTend RF Module User Guide
Configuration
8-bit (no parity or
7-bit (any parity)
8-bit even
8-bit odd
8-bit mark
8-bit space
Command descriptions
43

Advertisement

Table of Contents
loading

Table of Contents