Ward Consoles - Tunstall FlamencoIP Technical Manual

Hide thumbs Also See for FlamencoIP:
Table of Contents

Advertisement

14. Servicing
14.9

Ward consoles

Functions
BUS-C
ComStation
Inspection interval: 3 months
 Are the housing and connection cable un-
damaged and free of contamination?
 Are both plugs of the connection cable
seated firmly and are the screws screwed
in?
 Is the display easily readable?
 Is a fault in the nurse call system shown
on the display? If so, locate the fault and
remedy it.
 Are calls of the ward indicated by a call
tone and shown on the display?
Inspection interval: 12 months
 Can you answer the call by pressing the
corresponding push button or automatic
button?
 For calls with speech possibility: Is a
speech connection to the call location es-
tablished when a call is answered?
 Can both conversation partners hear at an
appropriate volume and understand each
other? Test using the microphone and
loudspeaker and test using the handset.
 For the "Call" call type: Can you cancel the
call remotely?
 For the "Door Call" call type: Can you trig-
ger the door opening mechanism to let the
person at the door in?
 For other call types: Can you close the
speech connection to the call location?
96
Order no.
77 0605 50
IP
Flamenco
- Technical Manual - 00 8813 52, 03/18 (Rev. 1.0)

Advertisement

Table of Contents
loading

Table of Contents