14. Servicing
Inspection measures
Call switch/WC with cancel switch
Inspection interval: 3 months
 Is the housing undamaged and free of
contamination?
 Can a call be triggered by pressing the red
call button?
 Do the location and reassurance lights of
the red call switch work?
 Does the switch emit an acoustic acknowl-
edgement of the call initiation?
 Can a WC call be cancelled using the grey
cancel button?
 Does the LED next to the cancel button
light up when a WC call that can be can-
celled with this cancel button is activated?
 If the optional "Call tone" function is acti-
vated via configuration on this switch,
check additionally: Does the switch emit a
call tone after an overflow time during ac-
tivated staff presence if a call has been in-
itiated in another room of the ward?
Overflow time according to operating
mode and configuration in the SystemOr-
ganizer.
Call switch with privacy switch
Inspection interval: 3 months
 Is the housing undamaged and free of
contamination?
 Can a call be triggered by pressing the red
call button?
 Do the location and reassurance lights of
the red call button work?
 Does the switch emit an acoustic acknowl-
edgement of the call initiation?
80
Order no.
77 0217 00 A
77 0217 00 C
77 0217 00 F
77 0218 00 A
77 0218 00 C