Pull cord call switches, Order No. 77 0215 0x..., Installation Instructions
Setting the call type (if needed)
You can set the call type to be initiated by the switch.
- Pull cord call switch, order no. 77 0215 00...; factory setting: Call. Optional setting: WC call.
- Pull cord call switch/WC, order no. 77 0215 01...; factory setting: WC call. Optional setting: Call
To set the call type: Within the first ten seconds after the power supply is switched on, you have to start with the pro‐
cedure described in the following (Alternatively, the connector of the switch can be pulled off briefly and then re-
plugged):
1. Pull and keep pulled the cord for approx. 10 seconds until the upper LED lights up white. (Sequence: After approx.
5 seconds the switch emits a beep and the upper LED lights up pink. After a further 5 seconds the switch emits a
second beep and the upper LED lights up white. Now release the cord.)
ü The upper LED signals the current setting for the call type:
Factory setting
Optional setting
2. Set the call type as follows:
Factory setting
Optional setting
3. To save the setting pull and keep pulled the pull cord until the switch emits a beep.
ü The new setting is saved.
Note! If you do not pull the cord within 30 seconds, the new setting is not saved.
ü The upper LED signals the set call type:
Factory setting
Optional setting
Mounting
Wall mounting on 1-gang back box (see Fig. B):
1. Screw the support ring 7 to the back box 8* with the back box
screws 5*. The openings 6 in the support ring 7 for the locking
hooks 2 of the switch module 1 must be located on the top
and on the bottom, see Fig. B.
2. Lead the connected connector 4* through the support ring 7
out of the back box 8*.
3. Place the switch module 1 in the frame 3. The LEDs of the
switch module 1 must be located on the left side, see Fig. B.
4. Plug the connected connector 4* to the socket on the rear
side of the switch module 1.
5. Press the switch module 1 together with the frame 3 onto the
support ring 7 until it engages.
6. The call handle 11 must be located between 10 and 20 cm
above the floor. Therefore shorten the pull cord 10 to the
desired length and re-knot it in the call handle 11.
Safety release
The safety release 9 opens, if the pulling force exceeds a limit
value. To re-establish the connection just plug the two parts of
the safety release together.
Dismantling
1. Lever the switch module 1 together with the frame 3 off the
support ring 7.
2. Remove the connector 4* from the switch module 1.
3. Undo the screws 5* of the support ring 7.
4. Remove the support ring 7.
00 8801 47, 05/15 (Rev. 5.0)
= Upper LED flashes once in red.
= Upper LED flashes once in green.
= Do not pull the cord.
= Pull the cord once.
= Upper LED flashes once in red.
= Upper LED flashes once in green.
Product leaflets 03/2018, page 18
5*
2
1
1
9
2
3
4* Connector, 3-pole
5* Back box screws
6
10
7
8* Back box, 1-gang
9
10 Pull cord
11 Call handle
*
11
4
English
6
4*
5*
8*
6
7
3
Switch module
Locking hooks
Frame
(order no. 70 0807 00)
Openings for the locking
hooks
Support ring
(solid wall: 17 0100 00,
partition wall: 17 5100 00)
Safety release
is not included with
product delivery.