Tunstall FlamencoIP Technical Manual page 175

Hide thumbs Also See for FlamencoIP:
Table of Contents

Advertisement

EN - Applications
Application: An external call device raises the call type "WC call".
DIP switch
(for settings
see below)
0V
0V
RAN
Room bus
(RAN)
+24V-Si
DIP switch 1–3:
***
Channel number
):
Channel 0
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
00 8801 97, 01/2017 (Rev. 6.0)
0V
A B
**
Button
)
Normally open (NO)
DIP switch 4:
Button contact type:
Normally closed
(NC)
Normally open
(NO)
***
) If functional units are requested, the call devices have to be
assigned to different channels. Refer to your installation plan
to find out, whether channel numbers have to be assigned.
Product leaflets 03/2018, page 60
*
)
LED:
Location light: I
Reassurance light: I
**
) Button:
Min. switching current: 0.1 mA, 5 V DC
Max. cable length at points 4, 5, 6 = 5 m
LED*)
**
Button
)
Normally closed (NC)
DIP switch 5–8:
Button function:
Call type "WC call"
The WC call is cancelled in the
nurse call system.
7
= 0.5 mA
max.
= 10 mA
max.
External call device
The location light
is on with a weak
light. When a call
is raised, it is on
with a bright light
as a reassurance
light.