8.5

Installing the xenon lamp in the lamp house

W
ARNING
XENON LAMP HANDLING OR SERVICE. ONLY TRAINED AND QUALIFIED TECHNICAL SERVICE PERSONNEL
ARE ALLOWED TO HANDLE THE XENON LAMP.
W
ARNING
C
AUTION
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer's instructions. The bulb is stable at room temperature, but may still explode if dropped or
otherwise mishandled. Whenever the lamp house, containing a xenon lamp, has to be dismantled or whenever
the protective container or cloth has to be removed from the xenon lamp, authorized protective clothing MUST
be worn!
W
ARNING
W
ARNING
W
ARNING
Necessary tools
Welder's jacket (not included in the safety kit that Barco offers).
Full face shield with neck protection.
Leather gloves with wrist protection.
Flat screw driver.
17 mm open-end wrench.
Torque wrench.
17 mm hexagon socket.
Torque screwdriver.
2 mm Allen socket.
5 mm Allen socket.
2,5 mm Allen wrench.
7 mm nut driver.
How to install the xenon lamp
1. Remove the UV blocker and side cover of the lamp house by releasing the retaining thumbscrews as illustrated.
Note: In case of a lamp replacement, the UV blocker will be already removed.
R5905312 HDF W SERIES 24/01/2013
:
DO NOT PERMIT UNAUTHORIZED PERSONNEL TO PERFORM OR ATTEMPT ANY PHASE OF
:
This procedure may only be performed by qualified technical service personnel.
:
Xenon compact arc lamps are highly pressurized. When ignited, the normal operating temperature
:
Always wear face protection (full face shield) when handling xenon lamps.
:
Always wear protective clothing (welder's jacket) when handling xenon lamps.
:
Always wear clean leather gloves with wrist protectors when handling xenon lamps.
8. Lamp and lamp house