5. Troubleshooting
Code 6031: "Board id: pmp write error" (Error)
Situation
Malfunction I²C communication on
the PMP board. Other input boards,
the Display board, the WARP module
and the Input & Communication unit
also have "Board id read errors".
Code 6032: "Board id: communication interface unknown format" (Warning)
Situation
Old projector software installed. The
ID parameters of the communication
interface are written in a format
which is not known by the projector
software.
Communication interface has invalid
firmware.
Corrupt projector software.
Code 6033: "Board id: communication interface not accessible" (Error)
Situation
Communication Interface board is
not installed.
Only the ID parameters of the
Communication Interface are not
accessible. The ID parameters of all
other boards are accessible.
The Board ID of all other boards
are also NOT accessible. This
may indicate a malfunction I²C
functionality on the PMP board.
Malfunction Communication
Interface.
Code 6034: "Board id: communication interface read error" (Error)
Situation
Malfunction Communication
Interface board. The projector
can not read from the installed
Communication Interface board.
Malfunction I²C communication on
the PMP board. The input boards,
the Display board and the WARP
module also have "Board id read
errors".
Code 6035: "Board id: communication interface write error" (Error)
Situation
Malfunction Communication
Interface board. The projector
can not write to the installed
Communication Interface board.
Malfunction I²C communication on
the PMP board. The input boards,
the Display board and the WARP
module also have "Board id read
errors".
44
Solution
Remove/disconnect the other boards from the I²C communication line one by one and
check if this error remains. Replace the board which makes this error goes away. If none
of the boards is the cause of this error, replace the PMP board. See chapter XXXX, to
see which boards are connected to the same internal communication line.
Solution
Check if the version of the installed projector software is the latest available version. The
latest version can be downloaded from https://my.barco.com.
Replace the communication interface. See "Removal of an input module", page 146.
Reinstall the latest projector software.
Solution
Install the Communication Interface board.
Ignore this error message unless other functionality of the Communication Interface fails
as well. If so, replace the Communication Interface board.
1.
Reboot the projector.
2.
Replace the PMP board. See "Replacing the PMP board", page 156.
Replace the Communication Interface board.
Solution
Replace the Communication Interface board.
Remove/disconnect the other boards from the I²C communication line one by one and
check if this error remains. Replace the board which makes this error goes away. If none
of the boards is the cause of this error, replace the PMP board. See chapter XXXX, to
see which boards are connected to the same internal communication line.
Solution
Replace the Communication Interface board.
Remove/disconnect the other boards from the I²C communication line one by one and
check if this error remains. Replace the board which makes this error goes away. If none
of the boards is the cause of this error, replace the PMP board. See chapter XXXX, to
see which boards are connected to the same internal communication line.
R5905312 HDF W SERIES 24/01/2013