Barco HDF W Series Service Manual page 128

Hide thumbs Also See for HDF W Series:
Table of Contents

Advertisement

8. Lamp and lamp house
Image 8-8
3. Release the four retaining thumbscrews of the UV blocker assembly as illustrated. Make sure that the UV blocker assembly
remains in its position while releasing the screws.
Image 8-9
4. Support the xenon lamp inside the Lamp House with one hand while removing the UV blocker assembly from the Lamp House.
Note that some xenon lamps are installed with an anode adaptation bushing.
Caution:
Ensure that you wear protective clothing, a full face shield and protective gloves.
Image 8-10
5. Slide the white anode socket, which is connected via a thick wire with the xenon lamp, upwards away from its position and then
remove the xenon lamp with anode socket from the Lamp House.
124
R5905312 HDF W SERIES 24/01/2013

Hide quick links: