5. Troubleshooting
1
3
Image 5-1
Code 2005: "Lamp stop failed" (Error)
Situation
Projector has no communication with
the LPS module.
2
Image 5-3
Image 5-5
34
2
Solution
1.
Check if the LPS communication cable (reference 1 image 5-3) is connected with
the CTLB-IN port of the first LPS unit in the LPS rack of the projector.
2.
Check if the CTLB-IN (LPS control) wire unit is connected with the Power
Distribution board (reference 9 image 5-4).
3.
Check if the yellow wire unit (reference 3 image 5-4 & image 5-5) between the
Power distribution board and the rear side of the Input & Communication unit
is properly connected.
1
3
4
Image 5-2
Image 5-4
R5905312 HDF W SERIES 24/01/2013
9
3