Barco HDF W Series Service Manual page 67

Hide thumbs Also See for HDF W Series:
Table of Contents

Advertisement

Code 7631: "Air out temp low" (Warning)
Situation
The ambient temperature in the
area of the projector is almost below
the minimum required operating
temperature of the projector.
Defect temperature sensor
(reference 11 image 5-27) which
measures the temperature at the air
outlet (projector rear side).
Image 5-27
Code 7632: "Air out temp high" (Warning)
Situation
Blocked air inlet channel.
The wire unit of the temperature
sensor (NTC) of the air outlet
is disconnected from the Power
distribution board.
Malfunction Fan Control board.
Defect temperature sensor
(reference 11 image 5-27) which
measures the temperature at the air
outlet (projector rear side).
Image 5-28
Code 7633: "Air out temp high" (Error)
This error code is probably preceded by the warning code 7632: "Air out temp high". The same troubleshooting table can be applied
to.
R5905312 HDF W SERIES 24/01/2013
Solution
Make sure that the ambient temperature is within specs: higher then 10°C (50°F). Let
the projector acclimate. Do not ignite the lamp, otherwise there is a risk for condensate.
Replace the temperature sensor at the air outlet channel.
11
Solution
Ensure that the air inlets are not blocked. Provide a sufficient free area at the front of the
projector so that fresh air can freely enter the air inlet channel.
Check if the wire unit (reference 11 image 5-28) of the temperature sensor is connected
with the power distribution board.
Replace the Fan Control Board. See "Replacing the Fan control board", page 278.
Replace the temperature sensor at the air outlet channel.
11
5. Troubleshooting
63