Voltage And Current Measurements; Power Measurements - Keysight Technologies 6811C Programming Manual

Ac power solutions
Hide thumbs Also See for 6811C:
Table of Contents

Advertisement

Voltage and current measurements

The SCPI interface provides a number of MEASure and FETCh queries that return
various components of rms voltage and current. For example, to read the AC
component of the rms voltage or current, use:
To read the sum of AC and DC components of the rms voltage or current, use:
To measure the DC voltage or current components, use:
To measure the maximum current amplitude and the current crest factor, use:

Power measurements

The MEASure and FETCh queries can return real, apparent, and reactive power
measurements as well as DC power and power factor using the following
commands:
Keysight Models 6811C, 6812C, and 6813C Programming Guide
MEASure:VOLTage:AC?
MEASure:CURRent:AC?
MEASure:VOLTage:ACDC?
MEASure:CURRent:ACDC?
MEASure:VOLTage:DC?
MEASure:CURRent:DC?
MEASure:CURRent:AMPLitude:MAXimum?
MEASure:CURRent:CREStfactor?
MEASure:POWer:AC:APParent?
MEASure:POWer:AC:REACtive?
MEASure:POWer:AC:REAL?
MEASure:POWer:AC:PFACtor?
MEASure:POWer:AC:TOTal?
MEASure:POWer:DC?
or
or
or
measures the AC component of apparent
power in VA
measures the reactive power
measures the in-phase component of power
in watts
returns the output power factor
measures the total real power being sourced
measures the DC component of power
Programming Examples
5