DISPlay:MODE

This command sets the display to show either normal instrument functions, or to
show a text message. Text messages are defined with DISPlay:TEXT:DATA.
Returned parameters <CRD>

DISPlay:TEXT

This command sets the character string that is displayed when the display mode
is set to TEXT. The argument is a quoted string limited to upper case alpha
characters and numbers. The display is capable of showing up to 14 characters. If
the string exceeds the display capacity, it will be truncated.
Returned parameters <SRD> (the last programmed string)

DISPlay:TEXT:CLEar

Clears text string set on DISP:TEXT.
Keysight Models 6811C, 6812C, and 6813C Programming Guide
Command syntax DISPlay[:WINDow]:MODE <mode>
Parameters NORMal | TEXT
*RST value NORMal
Examples
DISP:MODE TEXT
Query syntax DISPlay[:WINDow]:MODE?
Related commands DISP
Command syntax DISPlay[:WINDow]:TEXT[:DATA] <quoted_string>
Parameters <quoted_string>
*RST value Null string
Examples
DISP:TEXT "DO TEST1"
Query syntax DISPlay[:WINDow]:TEXT?
Related commands DISP
Command syntax DISPlay[:WINDow]:TEXT:CLEar
Parameters None
Examples
DISP:TEXT:CLE
Related commands DISP:MODE
DISP:TEXT
DISP:MODE
DISP:TEXT