3
Language Dictionary
Status Subsystem Commands
This subsystem programs the ac source status registers. The ac source has three
groups of status registers; Operation, Questionable, and Standard Event. The
Standard Event group is programmed with Common commands. The Operation
and Questionable status groups each consist of the following five registers:
– Condition
– Enable
– Event
– NTR Filter
– PTR Filter
Refer to
"Programming Examples"
Subsystem syntax
STATus
168
"Programming the Status Registers"
:PRESet
Presets all enable and transition registers to power-on
:OPERation
[:EVENt]?
Returns the value of the event register
:CONDition?
Returns the value of the condition register
:ENABle <n>
Enables specific bits in the Event register
:NTRansition <n> Sets the Negative transition filter
:PTRansition <n> Sets the Positive transition filter
:QUEStionable
[:EVENt]?
Returns the value of the event register
:CONDition?
Returns the value of the condition register
:ENABle <n>
Enables specific bits in the Event register
:NTRansition <n> Sets the Negative transition filter
:PTRansition <n> Sets the Positive transition filter
Keysight Models 6811C, 6812C, and 6813C Programming Guide
on page 259 in
for more information.
Chapter 5,