Measurement Subsystem (Power) Commands

This subsystem programs the power measurement capability of the ac source.
Two measurement commands are available: MEASure and FETCh. MEASure
triggers the acquisition of new measurement data before returning a reading.
FETCh returns a reading computed from previously acquired data.
For Keysight 6811C/6812C/6813C Option 020 only, all standard ac source
MEASure or FETCh functions are available for the Main Output of the ac source as
well as the Power Analyzer input. The SENSe:NSELect command selects the
measurement source that will return data.

Subsystem syntax

MEASure | FETCh

MEASure:POWer?

FETCh:POWer?
These queries return the DC component of the power being sourced at the output
terminals in watts.
Returned parameters <NR3>
92
[:SCALar]
:POWer
[:DC]?
:AC
[:REAL]?
:APParent? Returns VA
:REACtive? Returns VAR
:PFACtor?
Query syntax MEASure:[SCALar]:POWer[:DC]?
FETCh:[SCALar]:POWer[:DC]?
Parameters None
Examples
MEAS:POW?
Related commands MEAS:POW:AC?
Keysight Models 6811C, 6812C, and 6813C Programming Guide
Returns the DC component of power
Returns real power
Returns power factor