Voltage:triggered - Keysight Technologies 6811C Programming Manual

Ac power solutions
Hide thumbs Also See for 6811C:
Table of Contents

Advertisement

3
Language Dictionary

VOLTage:TRIGgered

This command selects the AC rms amplitude that the output waveform will be set
to during a triggered step or pulse transient.
The maximum peak voltage that the ac source can output is 425 V
includes any combination of voltage, voltage offset, and function shape values.
Therefore, the maximum value that can be programmed depends on the
peak-to-rms ratio of the selected waveform. For a sine wave, the maximum
voltage that can be programmed is 300 V
Returned parameters <NR3> (if the trigger level is not programmed, the immediate level is returned)
156
Command syntax [SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude] <NRf+>
Parameters For sine waves: 0 to 300 | MAXimum | MINimum
Unit V (rms voltage)
*RST value 0
Examples
VOLT:TRIG 120
Query syntax [SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude]?
Related commands VOLT
Keysight Models 6811C, 6812C, and 6813C Programming Guide
.
rms
VOLT:LEV:TRIG 150
VOLT:MODE
VOLT:OFFS
. This
peak
FUNC:SHAP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6812c6813c

Table of Contents