CALibrate:LEVel

CALibration:LEVel
This command can only be used in calibration mode. It is used to advance to the
next state in the calibration sequence.

CALibrate:PASSword

CALibration:PASSword
This command can only be used in calibration mode. It allows you to change the
calibration password. A new password is automatically stored in non-volatile
memory and does not have to be stored with CALibrate:SAVE. If the password is
set to 0, password protection is removed and the ability to enter the calibration
mode is unrestricted.
62
Command syntax CALibrate:LEVel <level>
CALibration:LEVel <level>
Parameters P1 | P2 | P3 | P4
Examples
CAL:LEV P2
Related commands CAL:STAT
Command syntax CALibrate:PASSword <NRf>
CALibration:PASSword <NRf>
Parameters 0 (default)
Examples
CAL:PASS 6812
Related commands CAL:STAT
Keysight Models 6811C, 6812C, and 6813C Programming Guide
CAL:SAVE
CAL:PASS 02.1997