VOLTage:PROTection

This command sets the overvoltage protection (OVP) level of the ac source. If the
peak output voltage exceeds the OVP level, then the output is disabled and the
Questionable Condition status register OV bit is set (refer to
Status Registers"
overvoltage condition can be cleared with the OUTPut:PROTection:CLEar
command after the condition that caused the OVP trip is removed. The OVP
always trips with zero delay and is unaffected by the OUTPut:PROTection:DELay
command.
Returned parameters <NR3>

VOLTage:PROTection:STATe

This command enables or disables the overvoltage protection feature.
Returned parameters <NR3>
Keysight Models 6811C, 6812C, and 6813C Programming Guide
on page 259 in
Command syntax [SOURce:]VOLTage:PROTection[:LEVel] <NRf+>
Parameters 0 to 500 | MAXimum | MINimum
Unit V (peak voltage)
*RST value MAXimum
Examples
VOLT:PROT 400
Query syntax [SOURce:]VOLTage:PROTection[:LEVel]?
Related commands OUTP:PROT:CLE
Command syntax [SOURce:]VOLTage:PROTection:STATe <bool>
Parameters 0 | 1 | OFF | ON
*RST value OFF
Examples
VOLT:PROT:STAT 1
Query syntax [SOURce:]VOLTage:PROTection:STATe?
Related commands VOLT:PROT
Chapter 5, "Programming
VOLT:PROT:LEV MAX
OUTP:PROT:DEL
VOLT:PROT:STAT ON
Language Dictionary
"Programming the
Examples"). An