Specifying A Dwell Time For Each List Point - Keysight Technologies 6811C Programming Manual

Ac power solutions
Hide thumbs Also See for 6811C:
Table of Contents

Advertisement

– By pressing the front panel Trigger key when the unit is operating in local
Continuous triggers
– By sending the following commands over the GPIB:
When the trigger system enters the Output Change state upon receipt of a trigger
(refer to
levels. When the triggered actions are completed, the trigger system returns to
the Idle state.

Specifying a dwell time for each list point

Each voltage and current list point has an associated dwell time specified by:
where <n> specifies the dwell time in seconds. The number of dwell points must
equal the number of output points. If a dwell list has only one value, that value will
be applied to all points in the output list. After each new output level or point is
programmed, the output remains at that point in the list for the programmed
dwell interval before the list advances to the next point. Only an ABORt command
can transfer the system out of the Dwelling state.
At the end of the dwell interval, the transition to the next state depends on
whether or not the list has completed its sequencing and the state of the
LIST:STEP command (refer to
If the list is completed, the trigger system returns to the Idle state.
– If the list is not completed, then the system reacts as follows:
Keysight Models 6811C, 6812C, and 6813C Programming Guide
mode.
TRIGger:SEQuence1:SOURce IMMediate
INITiate:CONTinuous:SEQuence1 ON
Figure
5-2), the triggered functions are set to their programmed trigger
LIST:DWELl <n>{, <n>}
LIST:STEP ONCE
LIST:STEP AUTO
Figure
5-2).
programs the trigger system to return to the Initiated
state to wait for the next trigger.
programs the trigger system to immediately execute
the next list point.
Programming Examples
5
249