Measure:power:ac:reactive; Measure:power:ac:pfactor - Keysight Technologies 6811C Programming Manual

Ac power solutions
Hide thumbs Also See for 6811C:
Table of Contents

Advertisement

3
Language Dictionary

MEASure:POWer:AC:REACtive?

FETCh:POWer:AC:REACtive?
These queries return the reactive power being sourced at the output terminals in
volt-amperes reactive (VAR). Reactive power is computed as:
Returned parameters <NR3>

MEASure:POWer:AC:PFACtor?

FETCh:POWer:AC:PFACtor?
These queries return the output power factor. The power factor is computed as:
Returned parameters <NR3>
94
VAR
=
Apparent Power
(
(
Query syntax MEASure:[SCALar]:POWer:AC:REACtive?
FETCh:[SCALar]:POWer:AC:REACtive?
Parameters None
Examples
MEAS:POW:AC:REAC?
Related commands MEAS:POW:AC:APP?
Real Power
PFactor
=
------------------------------- -
Apparent Power
Query syntax MEASure:[SCALar]:POWer:AC:PFACtor?
FETCh:[SCALar]:POWer:AC:PFACtor?
Parameters None
Examples
MEAS:POW:AC:PFAC?
Related commands MEAS:POW:AC:APP?
Keysight Models 6811C, 6812C, and 6813C Programming Guide
2
2
Real Power
)
(
)
)
FETC:POW:AC:REAC?
MEAS:POW:PFAC?
FETC:POW:AC:PFAC?
MEAS:POW:REAC?

Hide quick links: