5
Programming Examples
Register
Event
Enable
The outputs of the Operation Status register group are logically-ORed into the
OPER(ation) summary bit (7) of the Status Byte register.
Table 5-1
Bit
0
5
8
0
1
2
3
4
9
10
11
12
14
260
Command
STAT:OPER:EVEN?
STAT:OPER:ENAB? <n>
Bit configuration of status registers
Signal
Meaning
Operation status group
CAL
Interface is computing new cal constants
WTG
Interface is waiting for a trigger
CV
The output voltage is regulated
Questionable and questionable instrument isummary status groups
OV
The overvoltage protection circuit has tripped
OCP
The overcurrent protection circuit has tripped
SOA
The safe operating area protection has tripped
UNR
The output is unregulated
OT
An overtemperature condition has occurred
RI
The remote inhibit state is active
CLpeak
The peak current limit circuit is active
Rail
The rail protection circuit has tripped
CLrms
The rms current limit circuit is active
MeasOvld
Current measurement exceeded capability of low range
Keysight Models 6811C, 6812C, and 6813C Programming Guide
Description
A register that latches any condition that is passed through
the PTR or NTR filters. It is a read-only register that is
cleared when read.
A register that functions as a mask for enabling specific bits
from the Event register. It is a read/write register.