Frequency:mode; Frequency:slew - Keysight Technologies 6811C Programming Manual

Ac power solutions
Hide thumbs Also See for 6811C:
Table of Contents

Advertisement

3
Language Dictionary

FREQuency:MODE

This command determines how the output frequency is controlled during a
triggered output transient. The choices are as follows:
– FIXed: The output frequency is unaffected by a triggered output transient.
– STEP: The output frequency is programmed to the value set by
– PULSe: The output frequency is changed to the value set by
– LIST: The output frequency is controlled by the frequency list when a triggered
Returned parameters <CRD>

FREQuency:SLEW

This command sets the rate at which frequency changes for all programmed
changes in output frequency. Instantaneous frequency changes can be obtained
by sending MAXimum or INFinity. The SCPI keyword INFinity is represented by the
number 9.9E37.
Returned parameters <NR3>
124
FREQuency:TRIGgered when a triggered transient occurs.
FREQuency:TRIGgered for a duration determined by the pulse commands.
transient occurs.
Command syntax [SOURce:]FREQuency:MODE <mode>
Parameters FIXed | STEP | PULse | LIST
*RST value FIXed
Examples
FREQ:MODE FIX
Query syntax [SOURce:]FREQuency:MODE?
Related commands FREQ
Command syntax [SOURce:]FREQuency:SLEW[:IMMediate] <NRf+> | INFinity
Parameters 0 to 9.9E37 | MAXimum | MINimum | INFinity
*RST value MAXimum
Examples
FREQ:SLEW:IMM 75
Query syntax [SOURce:]FREQuency:SLEW[:IMMediate]?
Related commands FREQ
Keysight Models 6811C, 6812C, and 6813C Programming Guide
FREQ:TRIG
FREQ:SLEW MAX
FREQ:SLEW:MODE