3
Language Dictionary
VOLTage:OFFSet:MODE
This command determines how the DC offset voltage is controlled during a
triggered output transient. The choices are as follows:
– FIXed: The offset is unaffected by a triggered output transient.
– STEP: The offset is programmed to the value set by
– PULSe: The offset is changed to the value set by VOLTage:OFFSet:TRIGgered
– LIST: The offset is controlled by the voltage list when a triggered transient
Returned parameters <CRD>
160
VOLTage:OFFSet:TRIGgered when a triggered transient occurs.
for a duration determined by the pulse commands.
occurs.
Command syntax [SOURce:]VOLTage:OFFSet:MODE <mode>
Parameters FIXed | STEP | PULSe | LIST
*RST value FIXed
Examples
VOLT:OFFS:MODE FIX
Query syntax [SOURce:]VOLTage:OFFSet:MODE?
Related commands VOLT:OFFS
Keysight Models 6811C, 6812C, and 6813C Programming Guide
VOLT:OFFS:MODE:LIST
VOLT:OFFS:TRIG